This kit is not intended for use with single pipe indirect vent installations.
Direct vent furnace sidewall vent kit.
Do not use for roof top venting use this kit for side wall venting only.
The vent kit must terminate outside the structure and can be installed with the intake and exhaust pipes located side by side or with one pipe above the other.
All vent caps include a built in bird guard.
Direct vent counterflow the forced air circulation comfort heating system uses only outside air for combustion as the burners are completely sealed within the combustion chamber.
This is an alternative to the standard two pipe intake vent shown in the basic furnace installation instructions.
Failure to follow this warning could result in fire personal injury or death.
For clean comfortable heat when and where you want it the gas flame is completely sealed inside away from all contact with room air.
Refer to the furnace installation instructions for intake vent pipe sizing information.
Combustion products are discharged outdoors through the wall vent.
Do not use this kit to vent category i ii or iii furnaces do not apply to non condensing furnaces.
This vent kit is to be used with 2 vent systems.
So even if your furnace were to be approved for side wall venting b vent is not the proper type of vent pipe to use.
I0 635a september 2013 warning this vent kit is only to be used for venting category iv condensing furnaces.
Air necessary for combustion is drawn into the.
It also has a more attractive appearance on the outside of the building.
B vent is not airtight.
The york etc used a stainless flex pipe and not b vent.
Next b vent is for negative pressure draft systems only.
For use with direct vent furnace side wall vent kit function this vent kit is only to be used for venting category iv condensing furnaces do not use this kit to vent category i ii or iii furnaces do not apply to non condensing furnaces do not use for roof top venting how can we improve our technical specifications.
This eliminates the expense of a vent.
It provides an alternative to the traditional two pipes out the wall option.
The vent kit must terminate outside the structure and may be installed with the intake and exhaust pipes located side by side or with one pipe above the other.
Cvent 3 is for use with 3 in.
Direct venting uses a power ventilating blower or fan and in some models a heat exchanger plenum to cool outgoing gases passing through the building wall sidewall direct exhaust or roof or through an existing unused chimney through which a vent pipe is passed vertical direct exhaust.
The 2 3 side wall direct vent kit is for use with high efficient condensing furnaces.
Direct vent furnace side wall vent kit 0170k00001s.
Vent kit is not for use with single pipe indirect vent installations.